Section 6 The Selected Alternative Plan
EAA Storage Reservoirs Revised Draft PIR and EIS February 2006
6-29
be isolated and the discharge area dewatered for access for maintenance and
repairs.
Backflow gates will be installed at the discharge tube of each large pump. The
gates will be twin vertical-lift roller gates in a bulkhead configuration with relief
flaps located at the siphon discharge terminus as shown on Plate M-7. Primary
functions of the gates are to protect against backflow during pump shut-down
and non-pumping periods when the discharge pool is above the invert (summit),
and to prevent possibility of reverse siphoning due to incomplete breaking of
prime during shut-down of pumps. Each gate will be raised and lowered by a
single screw-stem with a Limitorque-type electric motor operator controlled from
within the station.
6.4.3.2.9 Gated Culverts
The gated culverts will use a slide type gate mechanism, which, because of the
head requirement, will need to be constructed of stainless steel. If increased
water-tightness is desired, resilient rubber seals will be part of the design.
The culvert gate will be a commercially available self-contained stainless steel
gate unit similar to those manufactured by Waterman Industries, Inc., and
Hydro Gate Corporation. The gate will be designed to meet American Water
Works Association leakage requirements for sluice gates. An electric operator
will operate the rising stem of design suitable for attaching to a concrete
bulkhead. The electric operator will include, but not be limited to, the motor,
actuator unit gearing, limit switch gearing, position limit switches, torque
switches, stem nut, declutch lever, high precision gate position potentiometer,
and hand wheel as a self-contained unit. The actuator will have sufficient
capacity to raise or lower the gate at a speed of 6-inch/min against the operating
heads. The hand wheel will operate in the clockwise direction to close. External
declutch lever will be padlockable in either the manual (hand wheel) or motor
mode.
6.4.3.2.10 Generator
Each gated culvert will have an emergency backup generator fueled with liquid
petroleum gas (LPG), located in a control room. A generator is required because
of the need to assure gated culvert operation during commercial power outages.
An underground LPG tank with sufficient capacity to assure operation of the
culvert gates for at least 7 days will be used.